TY - JOUR
T1 - Attenuation of eye movements evoked by a vestibular implant at the frequency of the baseline pulse rate
AU - Saginaw, Michael A.
AU - Gong, Wangsong
AU - Haburcakova, Csilla
AU - Merfeld, Daniel M.
N1 - Funding Information:
Manuscript received March 23, 2010; revised August 11, 2010; accepted October 25, 2010. Date of publication December 3, 2010; date of current version September 21, 2011. This work was supported in part by the U. S. Department of Health and Human Services under National Institutes of Health (NIH) Fellowship F31 DC006202, NIH Grant R01 DC03066, and Grant R01 DC008167, and in part by the European Commission under Project 225929. Asterisk indicates corresponding author. *M. A. Saginaw is with the MathWorks, Inc., Natick, MA 01760 USA (e-mail: [email protected]).
PY - 2011/10
Y1 - 2011/10
N2 - We are developing a vestibular implant to electrically stimulate vestibular neurons in the semicircular canals in order to alleviate vertigo, which is a commonly occurring problem. However, since electrical stimulation causes synchronous (phase-locked) neural responses, such electrical stimulation might also cause inappropriate vestibuloocular eye movements, which might, in turn, cause visual blurring. We investigated the eye movements evoked in the guinea pig using electric stimulation with a constant rate of 250 pulses per second (pps), and measured 0.010° peak-to-peak eye movements on an average at 250 Hz, with an average peak velocity amplitude of 8.1°/s, which might cause visual blurring. However, after half an hour of stimulation, that component reduced to 1.6°/s (0.0020° peak-to-peak). The average time constant for this reduction was 5.0 min. After one week of constant stimulation, the 250-Hz response component was only slightly smaller, at 1.2°/s (0.0015° peak-to-peak). We conclude that although an electrical prosthesis with a resting rate of 250 pps may cause some visual blurring when first turned on, such blurring is very likely to attenuate and be imperceptible within several minutes.
AB - We are developing a vestibular implant to electrically stimulate vestibular neurons in the semicircular canals in order to alleviate vertigo, which is a commonly occurring problem. However, since electrical stimulation causes synchronous (phase-locked) neural responses, such electrical stimulation might also cause inappropriate vestibuloocular eye movements, which might, in turn, cause visual blurring. We investigated the eye movements evoked in the guinea pig using electric stimulation with a constant rate of 250 pulses per second (pps), and measured 0.010° peak-to-peak eye movements on an average at 250 Hz, with an average peak velocity amplitude of 8.1°/s, which might cause visual blurring. However, after half an hour of stimulation, that component reduced to 1.6°/s (0.0020° peak-to-peak). The average time constant for this reduction was 5.0 min. After one week of constant stimulation, the 250-Hz response component was only slightly smaller, at 1.2°/s (0.0015° peak-to-peak). We conclude that although an electrical prosthesis with a resting rate of 250 pps may cause some visual blurring when first turned on, such blurring is very likely to attenuate and be imperceptible within several minutes.
KW - Biomedical engineering
KW - prosthetics
KW - translational medicine
KW - vestibuloocular reflex (VOR)
UR - https://www.scopus.com/pages/publications/80053208872
U2 - 10.1109/TBME.2010.2095850
DO - 10.1109/TBME.2010.2095850
M3 - Article
C2 - 21134812
AN - SCOPUS:80053208872
SN - 0018-9294
VL - 58
SP - 2732
EP - 2739
JO - IEEE Transactions on Biomedical Engineering
JF - IEEE Transactions on Biomedical Engineering
IS - 10 PART 1
M1 - 5648452