TY - JOUR
T1 - Automatic recovery of the optic nervehead geometry in optical coherence tomography
AU - Boyer, Kim L.
AU - Herzog, Artemas
AU - Roberts, Cynthia
N1 - Funding Information:
Manuscript received July 11, 2005; revised January 11, 2006. This work was supported in part by the Columbus Foundation. Asterisk indictaes corresponding author. *K. L. Boyer is with the Signal Analysis and Machine Perception Laboratory, Department of Electrical and Computer Engineering, The Ohio State University, 2015 Neil Ave., Columbus, OH 43210-1272 USA (e-mail: [email protected]). A. Herzog is with the Signal Analysis and Machine Perception Laboratory, Department of Electrical and Computer Engineering, The Ohio State University, Columbus, OH 43210-1272 USA. C. Roberts is with the Department of Ophthalmology and Biomedical Engineering Center, The Ohio State University, Columbus, OH 43210-1272 USA. Digital Object Identifier 10.1109/TMI.2006.871417
PY - 2006/5
Y1 - 2006/5
N2 - Optical coherence tomography (OCT) uses retroreflected light to provide micrometer-resolution, cross-sectional scans of biological tissues. OCT's first application was in ophthalmic imaging where it has proven particularly useful in diagnosing, monitoring, and studying glaucoma. Diagnosing glaucoma is difficult and it often goes undetected until significant damage to the subject's visual field has occurred. As glaucoma progresses, neural tissue dies, the nerve fiber layer thins, and the cup-to-disk ratio increases. Unfortunately, most current measurement techniques are subjective and inherently unreliable, making it difficult to monitor small changes in the nervehead geometry. To our knowledge, this paper presents the first published results on optic nervehead segmentation and geometric characterization from OCT data. We develop complete, autonomous algorithms based on a parabolic model of cup geometry and an extension of the Markov model introduced by Koozekanani, et al. to segment the retinal-nervehead surface, identify the choroid-nervehead boundary, and identify the extent of the optic cup. We present thorough experimental results from both normal and pathological eyes, and compare our results against those of an experienced, expert ophthalmologist, reporting a correlation coefficient for cup diameter above 0.8 and above 0.9 for the disk diameter.
AB - Optical coherence tomography (OCT) uses retroreflected light to provide micrometer-resolution, cross-sectional scans of biological tissues. OCT's first application was in ophthalmic imaging where it has proven particularly useful in diagnosing, monitoring, and studying glaucoma. Diagnosing glaucoma is difficult and it often goes undetected until significant damage to the subject's visual field has occurred. As glaucoma progresses, neural tissue dies, the nerve fiber layer thins, and the cup-to-disk ratio increases. Unfortunately, most current measurement techniques are subjective and inherently unreliable, making it difficult to monitor small changes in the nervehead geometry. To our knowledge, this paper presents the first published results on optic nervehead segmentation and geometric characterization from OCT data. We develop complete, autonomous algorithms based on a parabolic model of cup geometry and an extension of the Markov model introduced by Koozekanani, et al. to segment the retinal-nervehead surface, identify the choroid-nervehead boundary, and identify the extent of the optic cup. We present thorough experimental results from both normal and pathological eyes, and compare our results against those of an experienced, expert ophthalmologist, reporting a correlation coefficient for cup diameter above 0.8 and above 0.9 for the disk diameter.
KW - Contour segmentation
KW - Glaucoma
KW - Gradient descent
KW - Image segmentation
KW - Markov models
KW - Optic cup
KW - Optic disk
KW - Optic nervehead
KW - Optical coherence tomography
UR - https://www.scopus.com/pages/publications/33646426631
U2 - 10.1109/TMI.2006.871417
DO - 10.1109/TMI.2006.871417
M3 - Article
C2 - 16689260
AN - SCOPUS:33646426631
SN - 0278-0062
VL - 25
SP - 553
EP - 570
JO - IEEE Transactions on Medical Imaging
JF - IEEE Transactions on Medical Imaging
IS - 5
ER -