TY - JOUR
T1 - Nuclear magnetic resonance imaging with hyperpolarised helium-3
AU - Ebert, M.
AU - Grossmann, T.
AU - Heil, W.
AU - Otten, W. E.
AU - Surkau, R.
AU - Leduc, M.
AU - Bachert, P.
AU - Knopp, M. V.
AU - Schad, L. R.
AU - Thelen, M.
N1 - Funding Information:
that 3He MRI is a powerful method for imaging air spaces. This technique offers the possibility of investigating physiological and pathophysiological features of pulmonary ventilation and differences in its regional distribution. Mapping of local pulmonary ventilation will become possible. This method will be valuable in the demonstration of regional tissue differences in patients with chronic obstructive pulmonary disease, emphysema, bronchitis, and bronchiolitis. Mapping of regional ventilation is important in the preoperative assessment of local lung function before thoracic surgery for bronchogenic carcinoma or bulla resection and in diagnostic work-up before volume reduction surgery or single lung transplantation. After the development of a breathing mask for inhalation and recovery of 3 He, and construction of appropriate radio-frequency antenna systems, this technique will have reached ready for clinical research and application. This experiment was supported by the Human Capital and Mobility Program of the European Union within the network Polarised beams and targets and by the Federal Ministry for Research and Technology in Germany (contract number 03-Ot4MAI). We thank D Hofinann for preparing the transportable ’He cells; M Bock and H Nilgens for their advice in setting up the ’He MRI sequences; G van Kaick and W J Lorenz for their support; H Gross and F-P Boroch, Siemens Medical Systems, for technical assistance; and Schott Glaswerke Mainz for producing the special glassware.
PY - 1996/5/11
Y1 - 1996/5/11
N2 - Background. Magnetic resonance imaging (MRI) relies on magnetisation of hydrogen nuclei (protons) of water molecules in tissue as source of the signal. This technique has been valuable for studying tissues that contain significant amounts of water, but biological settings with low proton content, notably the lungs, are difficult to image. We report use of spin-polarised helium-3 for lung MRI. Methods. A volunteer inhaled hyperpolarised 3He to fill the lungs, which were imaged with a conventional MRI detector assembly. The nuclear spin polarisation of helium, and other noble gases, can be greatly enhanced by laser optical pumping and is about 105 times larger than the polarisation of water protons. This enormous gain in polarisation easily overcomes the loss in signal due to the lower density of the gas. Findings. The in-vivo experiment was done in a whole-body MRI scanner. The 3He image showed clear demarcation of the lung against diaphragm, heart, chest wall, and blood vessels (which gave no signal). The signal intensity within the air spaces was greatest in lung regions that are preferentially ventilated in the supine position; less well ventilated areas, such as the apices, showed a weaker signal. Interpretation. MRI with hyperpolarised 3He gas could be an alternative to established nuclear medicine methods. The ability to image air spaces offers the possibility of investigating physiological and pathophysiological processes in pulmonary ventilation and differences in its regional distribution.
AB - Background. Magnetic resonance imaging (MRI) relies on magnetisation of hydrogen nuclei (protons) of water molecules in tissue as source of the signal. This technique has been valuable for studying tissues that contain significant amounts of water, but biological settings with low proton content, notably the lungs, are difficult to image. We report use of spin-polarised helium-3 for lung MRI. Methods. A volunteer inhaled hyperpolarised 3He to fill the lungs, which were imaged with a conventional MRI detector assembly. The nuclear spin polarisation of helium, and other noble gases, can be greatly enhanced by laser optical pumping and is about 105 times larger than the polarisation of water protons. This enormous gain in polarisation easily overcomes the loss in signal due to the lower density of the gas. Findings. The in-vivo experiment was done in a whole-body MRI scanner. The 3He image showed clear demarcation of the lung against diaphragm, heart, chest wall, and blood vessels (which gave no signal). The signal intensity within the air spaces was greatest in lung regions that are preferentially ventilated in the supine position; less well ventilated areas, such as the apices, showed a weaker signal. Interpretation. MRI with hyperpolarised 3He gas could be an alternative to established nuclear medicine methods. The ability to image air spaces offers the possibility of investigating physiological and pathophysiological processes in pulmonary ventilation and differences in its regional distribution.
UR - https://www.scopus.com/pages/publications/0039669134
U2 - 10.1016/S0140-6736(96)90940-X
DO - 10.1016/S0140-6736(96)90940-X
M3 - Article
C2 - 8622506
AN - SCOPUS:0039669134
SN - 0140-6736
VL - 347
SP - 1297
EP - 1299
JO - Lancet
JF - Lancet
IS - 9011
ER -