TY - JOUR
T1 - The Preventable Shunt Revision Rate
T2 - A Multicenter Evaluation
AU - Dave, Pooja
AU - Venable, Garrett T.
AU - Jones, Tamekia L.
AU - Khan, Nickalus R.
AU - Albert, Gregory W.
AU - Chern, Joshua J.
AU - Wheelus, Jennifer L.
AU - Governale, Lance S.
AU - Huntoon, Kristin M.
AU - Maher, Cormac O.
AU - Bruzek, Amy K.
AU - Mangano, Francesco T.
AU - Mehta, Vivek
AU - Beaudoin, Wendy
AU - Naftel, Robert P.
AU - Basem, Jade
AU - Whitney, Anna
AU - Shimony, Nir
AU - Rodriguez, Luis F.
AU - Vaughn, Brandy N.
AU - Klimo, Paul
N1 - Publisher Copyright:
© 2018 by the Congress of Neurological Surgeons.
PY - 2019/3/1
Y1 - 2019/3/1
N2 - BACKGROUND: The Preventable Shunt Revision Rate (PSRR) was recently introduced as a novel quality metric. OBJECTIVE: To evaluate the PSRR across multiple centers and determine associated variables. METHODS:Nine participating centers in NorthAmerica provided at least 2 years of consecutive shunt operations. Index surgery was defined as newshunt implantation, or revision of an existing shunt. For any index surgery that resulted in a reoperation within 90-days, index surgery information (demographic, clinical, and procedural) was collected and a decision made whether the failure was potentially preventable. The 90-day shunt failure rate and PSRR were calculated per institution and combined. Bivariate analyses were performed to evaluate individual effects of each independent variable on preventable shunt failure followed by a final multivariable model using a backward model selection approach. RESULTS: A total of 5092 shunt operations were performed; 861 failed within 90 days of index operation, resulting in a 16.9% combined 90-day shunt failure rate and 17.6% median failure rate (range, 8.7%-26.9%). Of the failures, 307 were potentially preventable (overall and median 90-day PSRR, 35.7% and 33.9%, respectively; range, 16.1%-55.4%). The most commonetiologies of avoidable failurewere infection (n=134, 44%) and proximal catheter malposition (n = 83, 27%). Independent predictors of preventable failure (P < .05) were lack of endoscopy (odds ratio [OR] = 2.26), recent shunt infection (OR = 3.65), shunt type (OR = 2.06) and center. CONCLUSION: PSRR is variable across institutions, but can be 50% or higher. While the PSRR may never reach zero, this study demonstrates that overall about a third of early failures are potentially preventable.
AB - BACKGROUND: The Preventable Shunt Revision Rate (PSRR) was recently introduced as a novel quality metric. OBJECTIVE: To evaluate the PSRR across multiple centers and determine associated variables. METHODS:Nine participating centers in NorthAmerica provided at least 2 years of consecutive shunt operations. Index surgery was defined as newshunt implantation, or revision of an existing shunt. For any index surgery that resulted in a reoperation within 90-days, index surgery information (demographic, clinical, and procedural) was collected and a decision made whether the failure was potentially preventable. The 90-day shunt failure rate and PSRR were calculated per institution and combined. Bivariate analyses were performed to evaluate individual effects of each independent variable on preventable shunt failure followed by a final multivariable model using a backward model selection approach. RESULTS: A total of 5092 shunt operations were performed; 861 failed within 90 days of index operation, resulting in a 16.9% combined 90-day shunt failure rate and 17.6% median failure rate (range, 8.7%-26.9%). Of the failures, 307 were potentially preventable (overall and median 90-day PSRR, 35.7% and 33.9%, respectively; range, 16.1%-55.4%). The most commonetiologies of avoidable failurewere infection (n=134, 44%) and proximal catheter malposition (n = 83, 27%). Independent predictors of preventable failure (P < .05) were lack of endoscopy (odds ratio [OR] = 2.26), recent shunt infection (OR = 3.65), shunt type (OR = 2.06) and center. CONCLUSION: PSRR is variable across institutions, but can be 50% or higher. While the PSRR may never reach zero, this study demonstrates that overall about a third of early failures are potentially preventable.
KW - Metrics
KW - Multicenter
KW - Preventable shunt revision rate
KW - Quality
KW - Shunt malfunction
UR - https://www.scopus.com/pages/publications/85055914395
U2 - 10.1093/neuros/nyy263
DO - 10.1093/neuros/nyy263
M3 - Article
C2 - 29982642
AN - SCOPUS:85055914395
SN - 0148-396X
VL - 84
SP - 788
EP - 797
JO - Clinical Neurosurgery
JF - Clinical Neurosurgery
IS - 3
ER -