TY - JOUR
T1 - Ultrasound Features and Performance of Afirma Gene Sequencing Classifier in Cytologically Indeterminate Thyroid Nodules
AU - Azaryan, Irina
AU - Endo, Mayumi
AU - Sipos, Jennifer A.
AU - Ma, Jianing
AU - Peng, Jing
AU - Nabhan, Fadi
N1 - Publisher Copyright:
© 2024 Endocrine Society. All rights reserved.
PY - 2024/3/1
Y1 - 2024/3/1
N2 - Background: Cytologically indeterminate thyroid nodules (ITN) pose a management challenge. Here we analyze if adding ultrasound characteristics to Afirma Genome Sequence Classifier (GSC) results increases GSC diagnostic performance. Methods: We retrospectively analyzed 237 GSC-tested Bethesda III/IV ITNs between July 2017 and December 2019 and classified them by American Thyroid Association (ATA) and the Thyroid Imaging Reporting and Data System (TIRADS) of the American College of Radiology. Results: The benign call rate was higher in Bethesda III ITNs with TIRADS <5 vs TIRADS 5 (89% vs 68%. P = .015). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of GSC in ATA high-risk Bethesda III ITNs vs lower were 100% vs 80% (P = 1), 89.5% vs 91.5% (P = .67), 66.7% vs 25% (P = .13), and 100% vs 99.2% (P = 1), respectively, and for TIRADS 5 vs <5 were 100% vs 80% (P = 1), 88.2% vs 91.4% (P = .65), 71.4% vs 23.5% (P = .06), and 100% vs 99.3% (P = 1). The sensitivity, specificity, PPV, and NPV of GSC in high-risk ATA Bethesda IV ITNs vs lower were 66.7% vs 100% (P = .42), 83.3% vs 85.7% (P = 1), 66.7% vs 64.3% (P = 1), and 83.3% vs 100% (P = .3), respectively, and for TIRADS 5 vs <5 were 66.7% vs 90% (P = .42), 88.9% vs 83.8% (P = 1), 66.7% vs 60% (P = 1), and 88.9% vs 96.9% (P = .39). Conclusion: Sensitivity, specificity, NPV, and PPV of GSC were not significantly different in ATA high-risk and TIRADS 5 ITNs compared to ATA < high-risk and TIRADS 1-4 ITNs.
AB - Background: Cytologically indeterminate thyroid nodules (ITN) pose a management challenge. Here we analyze if adding ultrasound characteristics to Afirma Genome Sequence Classifier (GSC) results increases GSC diagnostic performance. Methods: We retrospectively analyzed 237 GSC-tested Bethesda III/IV ITNs between July 2017 and December 2019 and classified them by American Thyroid Association (ATA) and the Thyroid Imaging Reporting and Data System (TIRADS) of the American College of Radiology. Results: The benign call rate was higher in Bethesda III ITNs with TIRADS <5 vs TIRADS 5 (89% vs 68%. P = .015). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of GSC in ATA high-risk Bethesda III ITNs vs lower were 100% vs 80% (P = 1), 89.5% vs 91.5% (P = .67), 66.7% vs 25% (P = .13), and 100% vs 99.2% (P = 1), respectively, and for TIRADS 5 vs <5 were 100% vs 80% (P = 1), 88.2% vs 91.4% (P = .65), 71.4% vs 23.5% (P = .06), and 100% vs 99.3% (P = 1). The sensitivity, specificity, PPV, and NPV of GSC in high-risk ATA Bethesda IV ITNs vs lower were 66.7% vs 100% (P = .42), 83.3% vs 85.7% (P = 1), 66.7% vs 64.3% (P = 1), and 83.3% vs 100% (P = .3), respectively, and for TIRADS 5 vs <5 were 66.7% vs 90% (P = .42), 88.9% vs 83.8% (P = 1), 66.7% vs 60% (P = 1), and 88.9% vs 96.9% (P = .39). Conclusion: Sensitivity, specificity, NPV, and PPV of GSC were not significantly different in ATA high-risk and TIRADS 5 ITNs compared to ATA < high-risk and TIRADS 1-4 ITNs.
KW - Afirma GSC
KW - molecular test
KW - thyroid nodules
UR - http://www.scopus.com/inward/record.url?scp=85184939322&partnerID=8YFLogxK
U2 - 10.1210/jendso/bvae010
DO - 10.1210/jendso/bvae010
M3 - Article
AN - SCOPUS:85184939322
SN - 2472-1972
VL - 8
JO - Journal of the Endocrine Society
JF - Journal of the Endocrine Society
IS - 3
ER -