TY - JOUR
T1 - Validation of real-time three-dimensional echocardiography for quantifying left ventricular volumes in the presence of a left ventricular aneurysm
T2 - In vitro and in vivo studies
AU - Qin, Jian Xin
AU - Jones, Michael
AU - Shiota, Takahiro
AU - Greenberg, Neil L.
AU - Tsujino, Hiroyuki
AU - Firstenberg, Michael S.
AU - Gupta, Pankaj C.
AU - Zetts, Arthur D.
AU - Xu, Yong
AU - Sun, Jing Ping
AU - Cardon, Lisa A.
AU - Odabashian, Jill A.
AU - Flamm, Scott D.
AU - White, Richard D.
AU - Panza, Julio A.
AU - Thomas, James D.
N1 - Funding Information:
This study was supported, in part, by grant NCC9-60, National Aeronautics and Space Administration, Houston, Texas, and grant #9951522v from the American Heart Association Ohio Local Chapter, Columbus, Ohio, and grant #ROI-HL 56688-01A1 from the National Institutes of Health, Bethesda, Maryland.
PY - 2000
Y1 - 2000
N2 - OBJECTIVES: To validate the accuracy of real-time three-dimensional echocardiography (RT3DE) for quantifying aneurysmal left ventricular (LV) volumes. BACKGROUND: Conventional two-dimensional echocardiography (2DE) has limitations when applied for quantification of LV volumes in patients with LV aneurysms. METHODS: Seven aneurysmal balloons, 15 sheep (5 with chronic LV aneurysms and 10 without LV aneurysms) during 60 different hemodynamic conditions and 29 patients (13 with chronic LV aneurysms and 16 with normal LV) underwent RT3DE and 2DE. Electromagnetic flow meters and magnetic resonance imaging (MRI) served as reference standards in the animals and in the patients, respectively. Rotated apical six-plane method with multiplanar Simpson's rule and apical biplane Simpson's rule were used to determine LV volumes by RT3DE and 2DE, respectively. RESULTS: Both RT3DE and 2DE correlated well with actual volumes for aneurysmal balloons. However, a significantly smaller mean difference (MD) was found between RT3DE and actual volumes (-7ml for RT3DE vs. 22 ml for 2DE, p = 0.0002). Excellent correlation and agreement between RT3DE and electromagnetic flow meters for LV stroke volumes for animals with aneurysms were observed, while 2DE showed lesser correlation and agreement (r = 0.97, MD = -1.0 ml vs. r = 0.76, MD = 4.4 ml). In patients with LV aneurysms, better correlation and agreement between RT3DE and MRI for LV volumes were obtained (r = 0.99, MD = -28 ml) than between 2DE and MRI (r = 0.91, MD = -49 ml). CONCLUSIONS: For geometrically asymmetric LVs associated with ventricular aneurysms, RT3DE can accurately quantify LV volumes. (C) 2000 by the American College of Cardiology.
AB - OBJECTIVES: To validate the accuracy of real-time three-dimensional echocardiography (RT3DE) for quantifying aneurysmal left ventricular (LV) volumes. BACKGROUND: Conventional two-dimensional echocardiography (2DE) has limitations when applied for quantification of LV volumes in patients with LV aneurysms. METHODS: Seven aneurysmal balloons, 15 sheep (5 with chronic LV aneurysms and 10 without LV aneurysms) during 60 different hemodynamic conditions and 29 patients (13 with chronic LV aneurysms and 16 with normal LV) underwent RT3DE and 2DE. Electromagnetic flow meters and magnetic resonance imaging (MRI) served as reference standards in the animals and in the patients, respectively. Rotated apical six-plane method with multiplanar Simpson's rule and apical biplane Simpson's rule were used to determine LV volumes by RT3DE and 2DE, respectively. RESULTS: Both RT3DE and 2DE correlated well with actual volumes for aneurysmal balloons. However, a significantly smaller mean difference (MD) was found between RT3DE and actual volumes (-7ml for RT3DE vs. 22 ml for 2DE, p = 0.0002). Excellent correlation and agreement between RT3DE and electromagnetic flow meters for LV stroke volumes for animals with aneurysms were observed, while 2DE showed lesser correlation and agreement (r = 0.97, MD = -1.0 ml vs. r = 0.76, MD = 4.4 ml). In patients with LV aneurysms, better correlation and agreement between RT3DE and MRI for LV volumes were obtained (r = 0.99, MD = -28 ml) than between 2DE and MRI (r = 0.91, MD = -49 ml). CONCLUSIONS: For geometrically asymmetric LVs associated with ventricular aneurysms, RT3DE can accurately quantify LV volumes. (C) 2000 by the American College of Cardiology.
UR - https://www.scopus.com/pages/publications/0033864612
U2 - 10.1016/S0735-1097(00)00793-2
DO - 10.1016/S0735-1097(00)00793-2
M3 - Article
C2 - 10987618
AN - SCOPUS:0033864612
SN - 0735-1097
VL - 36
SP - 900
EP - 907
JO - Journal of the American College of Cardiology
JF - Journal of the American College of Cardiology
IS - 3
ER -